Volume : X, Issue : II, February - 2020
HEPA filter – golden half hour
Dr Shruti Dandawate, Dr Ajinkya Dandawate, Dr Rohit Dandawate, Dr Varsha Dandawate
Abstract :
Infection control is an important discipline concerned with prevention of nosocomial infections and in prevention of surgical site infections. Infections can spread through any means like blood, oral fluid, other secretions, surfaces, instruments, air etc. The most intangible means of pathogen transmission is air. The HEPA (High–efficiency particulate air) filter is capable of removing 99.97 percent of all particles larger than 0.3 microns in diameter. However the effect of HEPA filter on reducing the existent room air microbial burden takes time. In this study we analyzed how much time it takes for the HEPA filter to act in order to achieve a nil growth on culture plate. We were able to achieve nil growth on culture plate by 30 minutes hence emphasizing the need to switch on the HEPA filter half an hour prior to surgery for maximum benefits in prevention of surgical site infections.
Keywords :
Article:
Download PDF
DOI : 10.36106/ijar
Cite This Article:
HEPA FILTER‾GOLDEN HALF HOUR, Dr Shruti Dandawate, Dr Ajinkya Dandawate, Dr Rohit Dandawate, Dr Varsha Dandawate INDIAN JOURNAL OF APPLIED RESEARCH : Volume-10 | Issue-2 | February-2020
Number of Downloads : 170
HEPA FILTER‾GOLDEN HALF HOUR, Dr Shruti Dandawate, Dr Ajinkya Dandawate, Dr Rohit Dandawate, Dr Varsha Dandawate INDIAN JOURNAL OF APPLIED RESEARCH : Volume-10 | Issue-2 | February-2020
Our Other Journals...
-
International Journal of
Scientific Research Visit Website -
PARIPEX Indian Journal
of Research Visit Website -
Global Journal for
Research Analysis Visit Website