Volume : VIII, Issue : V, May - 2019
To assess & compare depth of penetration of an Epoxy amine based resin sealer in simulated lateral canals after manual, Sonic & Ultrasonic agitation- An in vitro Stereomicroscopic study
Dr. Darshan U. Heda, Dr. Rajesh Kubde, Dr. Pratima Shenoi, Dr. Gautam Badole, Dr. Aishwarya Akotkar
Abstract :
Objectives The aim of this study was to evaluate the efficacy of sonic and ultrasonic activation of epoxy-amine resin-based root canal sealer on penetration of the sealer into lateral canals compared to non-activated filling. Materials and method Thirty-six single-rooted human anterior teeth were decoronated and prepared, using the ProTaper rotary system (Dentsply Maillefer, Ballaigues, Switzerland) to F4. After the completion of the cleĺ procedures, lateral canals were created at 3 mm from the working length. The specimens were randomly divided into a control group (manual agitation) and two experimental groups that received a sealer application with either sonic or ultrasonic activation. The root canals were filled using cold lateral compaction and imageswere obtained from each lateral canals at 40Ă— magnification using a stereomicroscope. The sealer penetration was evaluated using a four-grade scoring system. The data were evaluated statistically using the Mann–Whitney U tests with a 95 % confidence level (P = 0.05). Results The ultrasonic activation resulted in a better sealer penetration compared with the non-activated and sonically activated groups (P < 0.001). Sonic activation also resulted in better sealer penetration compared to the non-activated group (P < 0.001). Conclusions The use of the ultrasonic activation of an epoxyamine resin-based sealer promoted greater sealer penetration into the lateral canals. Sonic activation was not effective as ultrasonic.
Keywords :
Article:
Download PDF
DOI : https://www.doi.org/10.36106/gjra
Cite This Article:
TO ASSESS & COMPARE DEPTH OF PENETRATION OF AN EPOXY AMINE BASED RESIN SEALER IN SIMULATED LATERAL CANALS AFTER MANUAL, SONIC & ULTRASONIC AGITATION- AN IN VITRO STEREOMICROSCOPIC STUDY, Dr.Darshan U. Heda, Dr. Rajesh Kubde, Dr. Pratima Shenoi, Dr. Gautam Badole, Dr. Aishwarya Akotkar GLOBAL JOURNAL FOR RESEARCH ANALYSIS : Volume-8 | Issue-5 | May-2019
Number of Downloads : 468
References :
TO ASSESS & COMPARE DEPTH OF PENETRATION OF AN EPOXY AMINE BASED RESIN SEALER IN SIMULATED LATERAL CANALS AFTER MANUAL, SONIC & ULTRASONIC AGITATION- AN IN VITRO STEREOMICROSCOPIC STUDY, Dr.Darshan U. Heda, Dr. Rajesh Kubde, Dr. Pratima Shenoi, Dr. Gautam Badole, Dr. Aishwarya Akotkar GLOBAL JOURNAL FOR RESEARCH ANALYSIS : Volume-8 | Issue-5 | May-2019